M8. Positions Test Figures
What It Is
A watch runs at a slightly different rate in each position, because
gravity acts on the balance differently in each. A positions test
measures it in several positions and sums the differences in a few
figures. The Positions Test pane (chapter 20) gives them, and so does
timegrapher session. They follow the figures Witschi’s timegraphers
use and the Swiss standard NIHS 93-10 (NIHS: Normes de l’Industrie Horlogère
Suisse, the Swiss watch industry’s standards; the project’s
math standards list them).
The Positions
| Common | Witschi | Group |
|---|---|---|
| DU, dial up | CH | horizontal |
| DD, dial down | CB | horizontal |
| CD, crown down | 9H | vertical |
| CL, crown left | 6H | vertical |
| CU, crown up | 3H | vertical |
| CR, crown right | 12H | vertical |
Witschi’s codes count round the dial with the crown at 3 o’clock, so crown up is 3H and crown right 12H.
How It Is Worked Out
Each position is read as timegrapher session reads a stretch: its
measured seconds, after its settle, with any masked time left out. A
position measured more than once is read together, or averaged first in
the indices. A position needs one whole 10 s reading to count.
In one state of wind (all positions at the same hours since full wind), with r each position’s rate and a its amplitude:
X = mean of r over the positions read the Average row
XH = mean of r over the horizontal positions
XV = mean of r over the vertical positions
D = largest r − smallest r the Largest Difference row
DV,DH = the same among the vertical or horizontal positions
DVH = XV − XH, and the same for amplitude vertical less horizontal
Di = r(6H) − r(CH) crown left less dial up
The Largest Difference row gives D for the rate, and the same for the amplitude and the beat error (as a size).
Across two states of wind, full wind and 24 hours after, with each position’s change Δr = r(24 h) − r(full):
Im = the Δr largest in size, crown right (12H) left out, signed
Im* = the same over all positions command line or MCP only
Ie = | X(24 h) − X(full) |, each X over the positions read in both
Why This Way
- Means over positions: a watch on the wrist turns through many positions, so the mean rate X is the nearest single figure to its rate worn.
- The largest difference D: how much the rate depends on position at all. A poised balance with a well-set hairspring gives a small D.
- Vertical against horizontal, DVH: in the horizontal positions the balance pivots rest on their ends; in the vertical ones on their sides, with more friction and a lower amplitude. DVH sums that split.
- Crown right left out of Im: as NIHS 93-10 takes it. The
Positions Test pane shows Im and Ie; the command line’s
sessionand the MCP server give Im* as well. - The same positions in both states for Ie, so a position measured only once can’t move the change in X.
When You’d Use This
- Regulating: X says where the watch runs on average; D and DVH say how much the positions differ before you adjust the rate.
- After service: compare the six positions and D with the figures from before.
- Full wind against 24 hours: Im and Ie say how much the rate moves as the mainspring lets down over a day, in each position and on average.
What It Helps Find
- A poise error: it can show as one vertical position far from the others.
- A large horizontal-vertical split (DVH): the balance pivots or jewels.
- A rate that runs away at 24 hours (large Im or Ie): isochronism (M12).
What It Can’t Tell You
- Whether the figures pass. The app gives no tolerance, verdict or pass and fail. Compare with the maker’s or the standard’s limits yourself.
- The cause. A large D or DVH says the positions differ, not why.
- Precision beyond the readings. Each position is one reading, with its own ± (M7); a short measurement in a noisy position gives a wide one.
Previous: M7. The ± and Correlated Readings · Next: M9. Steadiness Statistics
This page comes from the app's user guide at v1.0.1. See it on GitHub.